Leak Detection

Leak Detection

A wide range of leak detection systems provides fast detection and location reporting of potentially hazardous fluid leaks.

Two Channel Leak Detection System

Monitoring and Reporting of Leak Detection in Two Different Zones

Liebert Liqui-tect Two Channel Leak Detection SystemLiebert Liqui-tect two channel leak detection provides monitoring of two different areas with direct-read at the control unit location, as well as the ability to communicate with Liebert SiteScan Web centralized monitoring system or a building management system.

Liebert Liqui-tect direct-read leak detection system has two independent channels to monitor two different areas. Each channel can monitor up to 5,000 feet of Liebert LT500Y leak detection cable. 60Hz or 50Hz.

The system may be used to detect leaks from:

  • Glycol, condenser water, and chilled water cooling piping
  • Humidification feed water piping
  • Condensate pumps and drains
  • Unit and ceiling auxilliary drip pans
  • Overhead piping

Zone Leak Detection Sensor

Liebert LT460 Zone Leak Detection SensorLiebert LT460 sensor modules can monitor up to 100 feet of zone leak detection. This system operates a continuous monitoring for leakage, internal fault and power failure, providing a reliable warning of potentially hazardous moisture leaks.

Liebert Zone Leak Detection Sensor

Liebert LT460 zone leak detection sensor modules install quickly and work simply for reliable warning of potentially hazardous moisture leaks. The supervised zone leak detector uses up to 100 feet of flexible Liebert moisture sensing cable, offering protection for hard to reach spots and sensitive areas that require protection against leaks.

Liebert LT460 zone leak detection sensor can monitor up to 100 feet of Liebert LT500Y leak detection cable. Through a standard dry-contact output, the sensors are easily monitored by numerous monitoring systems, including Liebert thermal management units local alarm contact, Liebert SiteScan Web, and other dry contact monitors. 60Hz or 50Hz.

Point Leak Detection Sensors

Liebert LT410 Point Leak Detection SensorsEasy-to-Install Point Leak Detection Modules

Liebert LT410 point detection modules install quickly and work simply for reliable warning of potentially hazardous moisture leaks at critical points under a raised floor. A simple two-wire connection signals the alarms to a Liebert environmental unit monitor panel or at another monitoring panel.

Liebert LT point leak detection sensors provide single-point detection of leaks, using two gold-plated sensing probes. 50/60Hz, 24VAC.

Liebert LT410 has two independent outputs with the capacity to signal both a local alarm panel and a remote building management system or external equipment, such as motorized water shut-off valves.

The system may be used to detect leaks from:

  • Glycol, condenser water, and chilled water cooling piping
  • Humidification feed water piping
  • Unit and ceiling auxilliary drip pans
  • Overhead piping troughs

Point detection modules that install quickly and work simply for reliable warning of potentially hazardous moisture leaks at critical points under a raised floor. A simple two-wire connection signals the alarms to a Liebert environmental unit monitor panel or at another monitoring panel.

Leak Detection Cable

Liebert LT500Y Leak Detection CableLeak detection cable designed for use with Liebert Liqui-tect two-channel leak detection and reporting system, and Liebert LT460 zone leak detection sensors. The memory-resistant flexible cable is easy to install, and it includes mating connectors for quick extension or connection to the reading unit. Multi-wire design provides precise signaling.

Flexible Leak Detection Sensing Cable

Liebert LT500Y leak detection cable is designed for use with Liebert Liqui-tect two channel leak detection and reporting system, and Liebert LT460 zone leak detection sensors. The memory-resistant flexible cable is easy to install, and it includes mating connectors for quick extension or connection to the reading unit. Multi-wire design provides precise signaling.

Liebert LT500Y leak detection cable is thermally bonded cable rated at 176F (80C) and is plenum-rated. It is available in 15, 35 and 50 feet lengths. Mating connectors at each end simplify installation. 50/60 Hz.

Guests Online

We have 77 guests and no members online